Find EVRA 25 1inch Refrigeration Electromagnetic Valve, EVRA 25 Cast Iron Refrigeration Valve, EVRA 25 Danfoss Ammonia Solenoid Valve on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Liquid Heat Exchanger > 1'' Ammonia EVRA 25 Refrigeration Solenoid Valve

1'' Ammonia EVRA 25 Refrigeration Solenoid Valve

  • 1'' Ammonia EVRA 25 Refrigeration Solenoid Valve
  • 1'' Ammonia EVRA 25 Refrigeration Solenoid Valve
  • 1'' Ammonia EVRA 25 Refrigeration Solenoid Valve
  • 1'' Ammonia EVRA 25 Refrigeration Solenoid Valve

1'' Ammonia EVRA 25 Refrigeration Solenoid Valve

    Payment Type: L/C,T/T,Paypal,Western Union
    Terms of Trade: FOB,CFR,CIF,EXW
    Min. Order: 1 Piece/Pieces
    Delivery Time: 5 Days
    Packaging: Pallet,Carton,Box
    Productivity: 2800 sets per month
    Brand: BRANDO
    Transportation: Ocean,Land
    Place of Origin: NINGBO CHINA
    Supply Ability: 7 hundred /set per week
    Certificate: CE
    Port: Tianjin,Dalian,Xiamen

Basic Info

Model No.: EVRA 25

Product Description

1'' Ammonia EVRA 25 Refrigeration Solenoid Valve


Ammonia refrigeration Whether it is a single-stage compression or a two-stage compression system, to achieve complete and complete automation, it has an important premise, that is, to simplify and improve the traditional refrigeration process scientifically. Only in this way can automation be easier, safer and more reliable. The most important component inside is the refrigeration solenoid valve. Our EVRA 25 ammonia refrigeration solenoid valve is used in ammonia refrigeration automation system.


Technical data of 1'' Ammonia EVRA 25 Refrigeration Solenoid Valve:

Models Port size H1 H2 H4 L L2 Weight
Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Kg
EVRA 20 none 22-35 0.8 20 3.5 90 none none 11.1 280 1 25 none
EVRA 25 none 28-35 1.5 38 5.4 138 2.8 72 10 255 0.8 22 2.908
EVRA 32 none 38-45 1.9 47 4.4 111 2.1 53 11 280 1 25 4.088
EVRA 40 1 3/4 45 1.9 47 4.4 111 2.1 53 11 280 1.1 29 3.902
2 1/4 57 1.9 47 4.4 111 2.1 53 11 280 1.3 34 3.732


Physical map of 1'' inch cast iron body Ammonia EVRA 25 Refrigeration Solenoid Valve:

Physical map of 1'' inch cast iron body Ammonia EVRA 25 Refrigeration Solenoid ValvePhysical map of 1'' inch cast iron body Ammonia EVRA 25 Refrigeration Solenoid ValvePhysical map of 1'' inch cast iron body Ammonia EVRA 25 Refrigeration Solenoid Valve

Physical map of 1'' inch cast iron body Ammonia EVRA 25 Refrigeration Solenoid ValvePhysical map of 1'' inch cast iron body Ammonia EVRA 25 Refrigeration Solenoid Valve



Refrigeration Unit part (EVRA 25 Cast Iron Refrigeration Valve)




What's the difference between the fluorine refrigeration, ammonia refrigeration? The following is a detailed analysis of ammonia refrigeration system and fluorine refrigeration system similarities and differences.


One-time investment:
In general, large and medium-sized ammonia refrigeration system investment than the same scale of fluorine refrigeration system is less. This is mainly because the refrigeration units, equipment, pipes, valves and Other components of the fluorine refrigeration system are expensive, and the fluorine refrigeration system has a high degree of automation and relatively high investment.

Operating cost:
Ammonia refrigeration system has low working temperature, large refrigerating capacity, low energy consumption and low operating cost.

The refrigerant of fluorine refrigeration system has higher quality, smaller unit refrigerating capacity, higher energy consumption and higher operation cost.

Environmental characteristics:
Ammonia in the ammonia refrigeration system is a natural working substance. The ozone consumption coefficient ODP = 0, and the global warming coefficient GWP = 0. It has no pollution to the environment. Due to the destruction of the ozone layer, freon refrigerants in CFCS have been eliminated.

HCFCs has a smaller ODP and a smaller GWP on the earth, which has a certain destructive effect on the environment. Under international agreements, developing countries can use them by 2040.

Security:
When ammonia reaches 16 to 25 percent in the air, it can explode if exposed to open flames. Ammonia is toxic and can cause asphyxiation and frostbite. Poor security. Large capacity ammonia refrigeration systems should not be used in densely populated areas. F-22 is non-toxic, mixed with air, does not explode, and has good safety.


In densely populated areas (developing countries), f-22 systems and f-134a systems are more secure. Of course, if conditions permit, the application of CO2 refrigeration system is more environmentally friendly and safe.

Supply and return:
Ammonia system is usually connected with evaporator by bottom in and bottom out. Fluorine system is generally connected with evaporator by up and down connection to facilitate oil return.

Horizontal suction pipe of ammonia system should be inclined to circulating cylinder or gas-liquid separator; The horizontal suction pipe of the fluorine system should be inclined to the compressor.

Liquid supply method:
Ammonia system and fluorine system can supply liquid directly, liquid pump and gravity liquid to evaporator.

Application:
Ammonia and fluorine are medium temperature refrigerants with moderate pressure and temperature, suitable for refrigeration, refrigeration, air conditioning, industrial refrigeration, beer, pharmaceutical and other industries.

Fluorine systems are safer for direct evaporation air conditioning systems. The ammonia system can be air-conditioned by indirect cooling "superbrine".

Degree of automation control:
Fluorine refrigeration system automation, generally do not need manual operation, saving labor costs.

Ammonia refrigeration system mainly manual, low degree of automation, but good stability.

Solubility of oil:
The solubility of ammonia and oil is small, and the surface of ammonia Heat Exchanger is easy to form oil film, which affects heat transfer. Therefore, evaporator, condenser, accumulator, intercooler and oil ammonia separator should be drained regularly.

In the fluorine system, fluorine and oil dissolve each other, and the oil film does not form an oil film on the surface of the heat exchanger and does not affect heat transfer, but the excessive oil in the evaporator makes the evaporation temperature rise.

Fluorine system is generally equipped with automatic oil return device. The piping design and installation of the fluorine system shall be considered when setting the oil return elbow. Oil balance should be considered in parallel units.

Performance:
After years of design, installation and operation management, the ammonia refrigeration system is mature and stable.

Due to the irregular design, installation and operation management of the fluorine refrigeration system, coupled with the quality of the self-control components, despite the high degree of automation, the operational stability still needs to be improved, which is prone to burn-in accidents.


Welcome to your inquiry!

NINGBO BRANDO HARDWARE CO.,LTD

 


BRANDO is one of leading manufacturers of solenoids, armature assembly, and solenoid valve in China, located in China main sea port city -- NINGBO, the location with high convenience of shipment not only by air but also by ocean.

4


BRANDO has 4800 square meter workshops and around 50 employees, developed about 10 years from year 2008 by focusing on products quality, design, service, now with good reputation from all over the world and our annual output value increasing yearly by yearly, moreover, more than 90% of annual output value is from exporting brought from our high quality and best customer service. We highly believe to run the company and brand well should keep faith of BEST QUALITY, BEST ATTITUDE, and BEST CUSTOMER SERVICE.

1


BRANDO`s products range covering solenoid coil, solenoid valve armature assembly, various solenoid valves, fluid medium such like pneumatic, hydraulic, water, hot water, air, steam, gas, oil, chemical liquid and others. We supply OEM and ODM, all products widely applications for automotive, automation, textile industry, pneumatic , hydraulic, air and water treatment systems and so on.
Model series have such like Q22HD, 2W, 2S, US, 2L, 223, 6014, 0311, 0927, 0955, PU220, PU225, 2P, 2V, VX2120, QX, VX22, VX31/32/33, ZQDF, SCG, CA, DMF, 4V100, 4V200, 4V300, 4V400, VF, VZ, EVR, etc... Any request just feel free to contact our sales team, will response once get message, email or calling.
BRANDO company is approved by ISO9001:2008 system and managed by 5S management, with clean workshop environment and high precision machines and strict operation paperwork procedure to ensure the production well, save delivery time, and reduce any waste to satisfy all clients all over the world.
6


BRANDO company welcome clients from all over the world, we attend exhibition in many countries, such like America, Europe, Australia, Malaysia, Pakistan, Egypt, New Zealand, Poland, Germany, Korea, India, Indonesia, etc. We highly welcome your visit at our booth or our company.

2


Quick review of BRANDO products:

valve

valves2

pulse valve

armature and coils



Company Info

  • Company Name: NINGBO BRANDO HARDWARE CO.,LTD
  • Representative: Lu Jin Jun
  • Product/Service: Solenoid Valve Armatures , Solenoid Valve Coils , Pneumatic Solenoid Valves , Pneumatic Cylinders , Pulse Jet Diaphragm Valves , Pneumatic Components
  • Capital (Million US $): 1000,000RMB
  • Year Established: 2008
  • Total Annual Sales Volume (Million US $): US$5 Million - US$10 Million
  • Export Percentage: 81% - 90%
  • Total Annual Purchase Volume (Million US $): US$1 Million - US$2.5 Million
  • No. of Production Lines: 10
  • No. of R&D Staff: 5 -10 People
  • No. of QC Staff: 11 -20 People
  • OEM Services Provided: yes
  • Factory Size (Sq.meters): 3,000-5,000 square meters
  • Factory Location: Ningbo
  • Contact Person: Mr. Brandon Bao
  • Tel: 86-0574-83879820
Email to this supplier
  • *Subject:
  • To:

  • *Messages:
    Your message must be between 20-8000 characters