Shell and Tube Heat Exchanger as Condenser

Basic Info

Model No.:  BEN125-1.0-50/300

Product Description

Model NO.: BEN125-1.0-50/300 Refrigerant: CF2Cl2 Material: Copper Heat Transfer Mode: Regenerative Application Field: Petrochemical Industry Condition: New Shell and Tube Heat Exchanger: as Condenser Transport Package: Wooden Packaging Origin: Guangzhou China Condensation Forms: Water-Cooled Type: Steam Condenser Structural Form: Horizontal Form: Shell-Tube Certification: RoHS, ISO, CE, SGS Size and Material: Can Be Worked as Per Client Requirement Trademark: JIEMA Specification: ISO9001: 2008 HS Code: 8419500090                      Shell and Tube Heat Exchanger as  Condenser
Descripition:

shell and tube Heat Exchanger is a class of heat exchanger designs. It is the most common type of heat exchanger in oil refineries and Other large chemical processes, and is suited for higher-pressure applications. As its name implies, this type of heat exchanger consists of a shell (a large pressuere vessel) with a bundle of tubes inside it. One fluid runs through the tubes, and another fluid flows over the tubes (through the shell) to transfer heat between the two fluids. The set of tubes is called a tube bundle, and may be composed of several types of tubes: plain, longitudinally finned, etc.So,it is also called Tubular Heat Exchanger.
Shell and Tube Heat Exchanger as Condenser


Theory and Application:
Two fluids, of different starting temperatures, flow through the heat exchanger. One flows through the tubes (the tube side) and the other flows outside the tubes but inside the shell (the shell side). Heat is transferred from one fluid to the other through the tube walls, either from tube side to shell side or vice versa. The fluids can be either liquids or gases on either the shell or the tube side. In order to transfer heat efficiently, a large heat transfer area should be used, leading to the use of many tubes. In this way, waste heat can be put to use. This is an efficient way to conserve energy.

Shell and tube heat exchanger design:
Counter current heat exchangers are most efficient because they allow the highest log mean temperature difference between the hot and cold streams. Many companies however do not use single pass heat exchangers because they can break easily in addition to being more expensive to build. Often multiple heat exchangers can be used to simulate the counter current flow of a single large exchanger.

 
Applications and uses:
1.cooling of hydraulic fluid and oil in engines, transmissions and hydraulic power packs
2.heating other mediums,such as water,beverager,orange juice and other steam
3.they are extensively applied in chemical industrial,pertroleum and energy source and etc.
 
Material :
   Shell : Stainless steel  SS304# , SS316L#, carbon steel , copper 
   Tube : Stainless steel SS304# , SS316L# , carbon steel , copper 

Design selection need to provide the following parameters:

The Heat Exchanger Tube Specifications Φ20
DN Quantity of tube pass Quantity of heat exchanger tube Quantity of center raw tube  tube pass flow area(m²) Heat exchanger area(m²)
Tube length(mm)
1500 2000 3000 4500 6000
159 1 15 5 0.0030  1.4  1.9  2.8     
219 1 33 7 0.0066  3.1  4.1  6.2     
273 1 65 9 0.0131  6.1  8.2  12.3  18.4  24.5 
2 56 8 0.0056  5.3  7.0  10.6  15.8  21.1 
325 1 99 11 0.0199  9.3  12.4  18.7  28.0  37.3 
2 88 10 0.0088  8.3  11.1  16.6  24.9  33.2 
4 68 11 0.0034  6.4  8.5  12.8  19.2  25.6 
400 1 174 14 0.0350  16.4  21.9  32.8  49.2  65.8 
2 164 15 0.0165  15.5  20.6  30.9  46.4  61.8 
4 146 14 0.0073  13.8  18.3  27.5  41.3  55.0 
450 1 237 17 0.0477  22.3  29.8  44.7  67.0  89.3 
2 220 16 0.0221  20.7  27.8  41.5  62.2  82.9 
4 200 16 0.0101  18.8  25.1  37.7  56.5  75.4 
500 1 275 19 0.0553    34.6  51.8  77.8  103.7 
2 256 18 0.0257    32.2  48.3  72.4  96.5 
4 222 18 0.0112    27.9  41.8  62.8  83.7 
The Heat Exchanger Tube Specifications Φ25
DN Quantity of tube pass Quantity of heat exchanger tube Quantity of center raw tube  tube pass flow area(m²) Heat exchanger area(m²)
Tube length(mm)
1500 2000 3000 4500 6000
159 1 11 3 0.0038  1.3  1.7  2.6     
219 1 25 5 0.0087  2.9  3.9  5.6     
273 1 38 6 0.0132  4.5  6.0  9.0  13.4  17.9 
2 32 7 0.0055  3.8  5.0  7.5  11.3  15.1 
325 1 57 9 0.0197  6.7  9.0  13.4  20.1  26.9 
2 56 9 0.0097  6.6  8.8  13.2  19.8  26.4 
4 40 9 0.0035  4.7  6.3  9.4  14.1  18.8 
400 1 98 12 0.0339  11.5  15.4  23.1  34.6  46.2 
2 94 11 0.0163  11.1  14.8  22.1  33.2  44.3 
4 76 11 0.0066  9.0  11.9  17.9  26.9  35.8 
450 1 135 13 0.0468  15.9  21.2  31.8  47.7  63.6 
2 126 12 0.0218  14.8  19.8  29.7  44.5  59.4 
4 106 13 0.0092  12.5  16.7  25.0  37.5  50.0 
500 1 174 14 0.0603    27.3  41.0  61.5  82.0 
2 164 15 0.0284    25.8  38.6  58.0  77.3 
4 144 15 0.0125    22.6  33.9  50.9  67.9 

About Warranty
We promise 10 year guarantee, all reasonable relevant cost will be undertaken by us in the first year if our heat exchanger fail to work due to quality problem,
only the free repairing operation guide  is available in the rest of the 9 years via E-mail /Fax/Phone

Shell and Tube Heat Exchanger as Condenser


Company Profiles :
 Guangzhou Jiema is focus on the heat exchanger and spare parts manufacturer since 2005 with over 200 workers . 
Welcome to visit us : www.jiema-heatexchangers.com
We also provided technical service such as technical consultation, equipment update, capacity expansion scheme, maintenance and cleaning of the equipment.
Our objective is to supply you the correct specification of material to suit your particular application.

Shell and Tube Heat Exchanger as Condenser
Shell and Tube Heat Exchanger as Condenser
Obtained some part of the certificates :
CE , ISO9001:2008, TUV , SGS , Contract-credit 
Shell and Tube Heat Exchanger as Condenser
    
FAQ:
1. Q: How long can we deliver goods?
    A: 10-20days after payment.
2. Q: Where are our main markets?
    A: Our main market are North and South America, Southeast Asia, the Middle East, Africa.
3. Q:  What payment terms can you accept?
    A:  We can accept L/C, T/T, etc.
4. Q: Can you accept customized order?
    A: Yes, we accept, we have very professional technical group who can design the special products according to your basic parameter/ data sheet/ drawings or sample.
5. Q:  Do you have your own factory or just you are a trading company?
    A: We are direct manufacturer leader in China, one manufacturing center is located in Guangzhou, another in Hubei Province
6. Q: Is OEM order acceptable to your company?
    A: OEM is OK.
 

For any more details , You can click here or  via below :


 

Contact us if you need more details on Shell and Tube Heat Exchanger. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Condenser、Shell and Tube Heat Exchanger as Condenser. If these products fail to match your need, please contact us and we would like to provide relevant information.